SHYAsORBIT

MEPF and electrical consultancy · Kanpur

Site-ready MEPF design.

Electrical, HVAC, plumbing and fire-fighting design, calculated, coordinated and issued Good for Construction.

Illustrative
LT panel room
Illustrative
Fire pump room
Illustrative
AHU and chilled-water headers
E
ElectricalHT/LT, lighting, earthing
M
MechanicalHVAC and ventilation
P
PlumbingWater, drainage, STP
FP
Fire-fightingHydrants, sprinklers, FACP
Four disciplines, one drawing set

What we design

Each discipline is designed from calculations and issued with schedules, so the contractor builds from numbers, not guesses.

E

Electrical

HT/LT power systems, lighting and protection, designed for fault levels and selectivity, not only for load.

  • HT / LT distribution
  • Transformer and DG sizing
  • ACB · MCCB · MCB · RCCB
  • MCC and PCC panels
  • Busduct and rising mains
  • APFC with detuned reactors
  • DG synchronisation, ATS
  • Short-circuit and relay coordination
  • Cable derating, voltage drop
  • LED lighting, DALI controls
  • Earthing, LPS and SPD
  • UPS and ELV systems
M

Mechanical

Comfort cooling and ventilation built on a heat-load calculation and a defined air and water balance.

  • Heat load in TR
  • Psychrometric analysis
  • Chillers: screw, centrifugal
  • VRF / VRV, FCU, AHU, PAC
  • Duct sizing, static pressure
  • VAV and VFD control
  • Fresh-air and ACH design
  • Chilled-water piping, TDH
  • Kitchen and toilet exhaust
  • Staircase pressurisation
  • COP and IPLV selection
  • TAB and commissioning
P

Plumbing

Water supply, drainage and treatment sized by fixture units and verified against pressure at the last fixture.

  • Fixture-unit method
  • UG and OHT storage
  • Booster sets with VFD
  • PRV zoning of risers
  • Hazen-Williams head loss
  • Hot water: heat pump, solar
  • Soil, waste and vent stacks
  • Manholes and inspection chambers
  • STP: MBBR / SBR
  • Rain-water harvesting
  • Storm-water drainage
  • Water treatment and softening
FP

Fire-fighting

Suppression, detection and life safety designed against hydraulic calculations and the applicable fire code.

  • Wet riser and hydrants
  • Sprinklers: density-area
  • Jockey, main, standby pumps
  • Yard hydrant ring main
  • Landing valves, hose reels
  • Addressable FACP loops
  • Smoke and heat detection
  • Smoke extraction and dampers
  • Clean-agent suppression
  • Emergency lighting, exits
  • Fire tank sizing
  • Cause-and-effect matrix
From the plant room to the terrace

Where our design ends up

The installations our drawings describe: switchgear, cable routes, plant, pump rooms, risers and rooftop equipment.

Illustrative
LT panel room: ACB incomers, MCCB feeders, APFC
Illustrative
Cable tray and sprinkler main above a corridor
Illustrative
AHU, insulated chilled-water headers, foil-clad duct
Illustrative
Fire pump room: jockey, main and standby sets
Illustrative
Riser shaft: cold water, soil stack, wet riser
Illustrative
Terrace plant: air-cooled chiller and cooling tower

These six pictures are illustrations of typical installations, marked as such. Real photographs from your sites can replace them.

Design basis

What we calculate

Every size on a drawing traces back to a calculation. This is the working behind a typical design set.

EElectrical

Maximum demand
Connected load × demand and diversity factorskVA, transformer and DG rating
Voltage drop
I × (R cosφ + X sinφ) × L, checked to permitted %Cable size and run length
Fault level
Short-circuit study at each busIcu / Ics of ACB and MCCB
Discrimination
Time-current curves, IDMT relay settingsSelective tripping
Power factor
Reactive load, harmonic contentAPFC kVAR, reactor detuning
Earthing
Soil resistivity by Wenner methodElectrode type and pit count

MMechanical

Cooling load
Sensible and latent heat gainsTR, chiller or VRF capacity
Air quantity
Supply ΔT, ACH, fresh air per personCFM, AHU and FCU selection
Duct sizing
Equal friction or static regainFan static pressure, VFD duty
Water circuit
Flow in GPM, pipe friction, fittingsPump TDH, balancing valves
Plant efficiency
Part-load operationCOP and IPLV comparison
Ventilation
Occupancy, smoke and exhaust dutyFan and damper schedule

PPlumbing

Peak demand
Fixture-unit method, probability of usePipe size, flow in LPM
Head loss
Hazen-Williams, equivalent length of fittingsPump TDH, PRV zones
Storage
Daily demand, UG and OHT splitTank volumes in KL
Drainage load
Drainage fixture units, gradientStack and branch sizing
Sewage load
Per-capita flow, peaking factorSTP capacity in KLD
Hot water
Storage and recovery rateHeat pump or solar sizing

FPFire-fighting

Sprinkler hydraulics
Density-area method, remote areaPump flow and residual pressure
Hydrant demand
Simultaneous landing valve operationTank volume, pump rating
Pump set
Duty point on the system curveMain, jockey and diesel standby
Detection
Coverage per detector, addressable loopsFACP loops and device count
Smoke control
Pressure differential, extraction rateFans, dampers, interlocks
Egress
Travel distance, exit widthSignage and emergency lighting
Stage by stage

From brief to handover

Seven stages, each ending in a document or drawing set you can review and sign off.

  1. 00

    Brief and site survey

    Occupancy, utility availability, existing services, constraints.

    Survey notes
  2. 01

    Design basis report

    Load estimate, system options, codes and design criteria.

    DBR
  3. 02

    Schematic design

    Single line diagrams, P&IDs, riser diagrams, plant locations.

    SLD · P&ID
  4. 03

    Detailed design

    Layouts, sections, schedules and a services overlay with clash resolution.

    GFC drawings
  5. 04

    Tender

    Specifications, BOQ, vendor comparison, material approval sheets.

    BOQ · MAS
  6. 05

    Site support

    RFI replies, inspection against the inspection and test plan, drawing revisions.

    RFI log · ITP
  7. 06

    Testing and handover

    Witnessed tests, commissioning records, as-built drawings and O&M manuals.

    As-builts · O&M

Tests we witness before handover

  • Insulation-resistance (megger) tests
  • Earth-pit resistance measurement
  • Relay and breaker trip tests
  • Hydrostatic pressure tests on piping
  • Flushing and disinfection of water lines
  • Air and water balancing (TAB)
  • Pump performance runs
  • Fire alarm cause-and-effect test
Established 2026 · 20+ projects

Key projects

Hospitality, infrastructure and institutional work across Madhya Pradesh and Uttar Pradesh.

01

3 Star Hotel

Hospitality · Madhya Pradesh

02

Lloyds Infrastructure Pvt Ltd

Infrastructure · EPC contractor

03

GAIL Boys and Girls Hostel

Institutional · Uttar Pradesh

SHYAs ORBIT is an MEPF and electrical consultancy based in Kanpur, Uttar Pradesh. We work with owners, developers, architects and EPC contractors on residential, commercial, industrial, institutional, healthcare and hospitality buildings.

Our name reflects how we work: every system in a building moves around one shared core, and good design keeps all of them in step.

Er. Ramanujam(B.E - Electrical and Electronics Engineering)MEPF & ELECTRICAL CONSULTANT
Enquiries and support

Start a project

Message us on WhatsApp, email us, or fill in the brief below. For live projects, send RFIs and drawing queries to the support address.

WhatsApp

The fastest way to send a drawing, a photo or a quick question.

+91 70545 46600Chat on WhatsApp

Enquiries

New projects, quotations and design proposals.

enquiry@shyasorbit.comEmail an enquiry

Support

Site queries, RFIs, drawing revisions and clarifications on live projects.

support@shyasorbit.comEmail support
Shyam Nagar, Kanpur

Our office

Plot No-10, Ganga Nagar, Near Mohini Vatika Guest House, Shyam Nagar, Kanpur - 208015, Uttar Pradesh

The map above is a schematic. The buttons open the live location in Google Maps.

Project brief

Services needed

Your brief is ready. This page cannot send messages by itself. Send it on WhatsApp or by email, or copy it.

WhatsApp